Effective half-life
The real-world time it takes for the radioactivity in a patient's organ to fall by half, combining both the radioactive atom's own decay and the body's own clearance of the drug. It is always shorter than either process acting alone, and it is the number that actually drives how much radiation dose an organ receives.
Overview
The effective half-life (Teff) is the time required for the radioactivity of a radiopharmaceutical within an organ or the whole body to fall to half its original value under the combined action of radioactive decay (physical half-life, Tphys) and biological elimination (biological half-life, Tbiol). Because both processes remove activity in parallel and independently, their rate constants add: 1/Teff = 1/Tphys + 1/Tbiol, equivalently Teff = (Tphys x Tbiol)/(Tphys + Tbiol); Teff is always shorter than whichever of Tphys or Tbiol is shorter, and it converges towards the shorter of the two when the two half-lives differ greatly (for a radionuclide with a very long physical half-life and fast biological clearance, Teff approaches Tbiol, and vice versa).
Effective half-life is the quantity that actually appears in dosimetry calculations, because it describes how the true, measurable radioactivity in a source organ declines over time, which is exactly what a time-activity curve records and what must be integrated to obtain the time-integrated activity used in the MIRD formalism. It can be measured directly from serial quantitative imaging without needing to separately determine the physical and biological components.
A practical example: 177Lu has a physical half-life of about 6.65 days; if a PSMA-targeted ligand clears from the kidneys with a biological half-life of a few days, the effective half-life in the kidney will be shorter than 6.65 days, meaning the kidney's radiation exposure is delivered, and finishes, faster than lutetium-177's own decay alone would suggest.
- Gamma camera (rotates)
- Single photons (Tc-99m, Lu-177)
Showing the technology this term belongs to: Radioligand dosimetry.
Similar pages
not linked directly; found by shared links- TermMIRD formalism
Shares Time-activity curve (TAC), In vivo dosimetry and patient-specific quality assurance, Radioligand dosimetry.
- PersonDale L. Bailey
Shares In vivo dosimetry and patient-specific quality assurance, Radioligand dosimetry, Lutetium-177.
- TermActivity prescription: fixed versus dosimetry-guided dosing
Shares Time-activity curve (TAC), Radioligand dosimetry, Lutetium-177.
- IdeaAI segmentation to make voxel-level radioligand dosimetry practical at scale
Shares In vivo dosimetry and patient-specific quality assurance, Radioligand dosimetry, Lutetium-177.
- TermEquivalent dose and effective dose (sievert)
Shares In vivo dosimetry and patient-specific quality assurance, Radioligand dosimetry.
- TermBecquerel and curie (units of radioactivity)
Shares Decay correction, Lutetium-177.
- TermAbsorbed dose and the gray (Gy)
Shares In vivo dosimetry and patient-specific quality assurance, Radioligand dosimetry.
- BottleneckDosimetry standardisation for radioligand therapy
Shares In vivo dosimetry and patient-specific quality assurance, Radioligand dosimetry, Lutetium-177.